Features
50MHz Bandwidth, Dual Channel Delayed Sweep Built-In Delay Line TV Synchronization CH1 Output Z-Axis Modulation Input ALT Triggering Function Hold Off Function Trigger Level Lock Function Specifications
CRT | | Type | 6-inch rectangular type with internal graticule 0%, 10%, 90% and 100% markers. 8 x 10 div (1div=1cm) | Accelerating Potential
| 12kV | | Illumination | Continuously adjustable | Z-axis Input
| Input Impedance: Approx. 5kΩ Sensitivity:Above 3Vp-p Bandwidth:DC ~ 5MHz | VERTICAL SYSTEM | | Sensitivity | 5mV/div ~ 5V/div±3%,1mV ~ 2mV/div±5% | | Bandwidth | DC ~ 50MHz DC ~ 15MHz at 1 ~ 2mV/div | Rise Time
| 7ns (23.3ns for 1 ~ 2mV/div) | | Signal Delay | leading edge can be monitored | Input Impedance
| Approx. 1MΩ | Input Coupling
| AC, DC, GND | Vertical Mode
| CH1, CH2, DUAL, ADD, CH2 INV (Dual automatic switching ALT and CHOP) | HORIZONTAL SYSTEM | | A(main) Sweep Time | 0.1μs ~ 0.5s/div±3% 100ns ~ 50ms/div±5% (x 10 MAG) 10ns ~ 50ns±8% (x 10 MAG) | | B(delay) Sweep Time | 0.1μs ~ 0.5ms/div±3% 100ns ~ 50μs/div±5% (x 10 MAG) 10ns ~ 50ns/div±8% (x 10 MAG) | | Delay Time | 1μ s ~ 5ms,±5% | | Delay Time Jitter | Better than 1:10000 | TRIGGER | | Trigger Mode | AUTO, NORM, SINGLE | | Trigger Source | CH1, CH2, ALT, LINE, EXT | | Trigger Coupling | AC, DC, HF REJ, TV | | Trigger Slope | "+" or "-" | X-Y OPERATION | | Sensitivity | 5mV ~ 5V/div±4% | | X-axis Bandwidth | DC ~ 2MHz | | Phase Error | 3° or less from DC ~ 100kHz | OUTPUT SIGNAL | | Trigger Signal Output | Voltage: approx. 50mV/div into 50Ω | Calibrator Output
| 1kHz Square wave, 2Vp-p±2% | | POWER SOURCE | | | | AC 100V/120V/220V/230V±10%, 50Hz/60Hz | ACCESSORIES | | | User manual x 1 Power cord x 1 GTP-060A-4 Probe (10:1/1:1) x 2 | | DIMENSIONS & WEIGHT | | | | 310(W) x 150(H) x 455(D) mm Approx. 8.2kg |
|
|